Manufacturer data sheet

Cell at a glance

3500 mAh Rated capacity
3.65V Nominal voltage
12.78 Wh Nominal energy
10.2A Maximum current basis
1.5A Maximum charge current
18650 Cell format

Datasheet-verified specification

Full technical specification

Store SKUEVE-35V-18650-B1
Manufacturer / modelEVE INR18650/35V
Format / chemistry18650 / Li-ion
Rated capacity3500 mAh (minimum 3400 mAh)
Nominal voltage3.65V
Full-charge voltage4.2V
Discharge cutoff voltage2.5V
Standard charge current0.68A
Maximum charge current1.5A
Continuous discharge rating10.2A
Initial internal resistance<=30 mOhm
Weight50g
DimensionsDiameter 18.35+/-0.10 mm; height 65.10+/-0.15 mm
Charge temperature range0C to 50C
Discharge temperature range-20C to 60C
Cycle-life reference1000 cycles >=70% retention at standard charge/discharge.
ProtectionUnprotected industrial cell. The finished device or battery pack must provide appropriate protection.

Simple selection guide

Is this the right cell for your build?

Match the cell to the job, then confirm the manufacturer limits for the finished pack.

Best match

Low-current electronics, lighting, backup systems, sensors, and gentle energy-storage duty.

A better alternative when

Choose a power or hybrid cell for tools, RC, UAV, high-watt mobility, or other demanding loads.

Application guide

Where this cell fits

Fast guidance for common pack types.
Best fit

Low-current runtime packs, energy storage, backup power

Validate first

Moderate loads only after current and thermal validation

Avoid

Power tools, RC / UAV, high-watt mobility, vape devices

Keep the finished pack within every manufacturer voltage, current, and temperature limit.

Engineering limits

Current limits

Manufacturer continuous-discharge ratings only. Pulse and over-current laboratory values stay on BatteryRealData.
Continuous discharge rating 10.2A Planner reference
What this means

The displayed continuous limit comes from the matched manufacturer data sheet. Use design headroom and validate heat in the finished pack.

Show current and runtime examples Optional 1C references and idealized runtime estimates

Current envelope

Relative current values from the matched manufacturer data sheet. Bar length is comparative, not a recommendation.

1C
3.5A
Continuous
10.2A

Current and runtime translation

Idealized constant-current runtime based on nominal capacity. Real packs deliver less because voltage sag, heat, cutoff voltage, and losses matter.

0.2C / 0.7A
300 min
0.5C / 1.75A
120 min
1C / 3.5A
60 min
At continuous limit
20.59 min
These are mathematical estimates, not guaranteed run times or instructions to operate at the maximum rating.

Real discharge testing

Tested by BatteryRealData

This Shopify summary includes only tests at or below the published 10.2A continuous-current ceiling.

Highest measured raw capacity 1A constant-current test
EVE 35V 1A discharge plot showing voltage and cell temperature versus measured capacity
Voltage Cell temperature
Raw capacity
3493 mAh
Raw energy
12.73 Wh
Max observed temp
27.8C
Completed to the configured cutoff
Highest datasheet-range current 10A constant-current test
EVE 35V 10A discharge plot showing voltage and cell temperature versus measured capacity
Voltage Cell temperature
Raw capacity
3424 mAh
Raw energy
11.25 Wh
Max observed temp
64.4C
Completed to the configured cutoff

These curves are observed laboratory results, not operating recommendations. Voltage and temperature are plotted against measured raw capacity for the selected run.

5 datasheet-range discharge tests

Displayed test-current range: 1A to 10A

Best raw capacity
3493 mAh
Best raw energy
12.73 Wh
Published continuous-current ceiling
10.2A

Only tests inside the matched data sheet continuous-current range are summarized here. BatteryRealData may separately include controlled pulse or over-current research; those laboratory stress tests are not product ratings or operating instructions.

View datasheet-range graphs and test results

Pack planning aid

Current per cell calculator

Enter the total pack current and the number of parallel cells. This checks current sharing against the unconditional continuous value listed above.
Calculated current per cell 10.2A

Planning aid only. It assumes equal current sharing between matched cells. It does not account for heat, aging, imbalance, conductor resistance, duty cycle, enclosure airflow, or BMS limits.

Read before purchase and use

Safety warning for lithium-ion battery usage

Customers should understand lithium-ion battery handling and safety before purchase. Lithium-ion cells can cause fire, burns, venting, or explosion if misused, overcharged, shorted, crushed, punctured, overheated, or physically damaged.

Use only with a compatible lithium-ion charger, BMS, or protection circuit designed for the cell voltage, current, and temperature limits. Never leave batteries charging unattended. Charge and store on a fire-resistant surface away from combustible materials.

By purchasing and using lithium-ion cells, the user assumes responsibility for correct handling, storage, charging, pack design, and application suitability.

Important usage guidelines

  • Not for use in e-cigarettes, vape devices, or similar devices.
  • Always use in a protected battery pack or properly controlled test fixture.
  • Do not exceed the data sheet maximum charge voltage.
  • Do not discharge below the recommended system cutoff voltage.
  • Do not charge or discharge outside the data sheet temperature limits.
  • Do not carry loose cells in pockets, bags, or toolboxes where they can contact keys, coins, tools, or other metal objects.
  • Store and ship cells in protective cases or insulated packaging.
  • Do not use batteries with torn wrappers, missing insulator rings, dents, rust, odor, leakage, deformation, heat damage, or visible damage.
  • Do not solder directly onto cell terminals. Use proper spot-welding methods only.
  • Do not alter, dismantle, puncture, crush, burn, immerse in liquid, or expose cells to open flame.
  • Keep away from children and pets.
For resellers

Pass all safety information to end users to promote safe handling, correct pack design, and proper use.

Common questions

EVE 35V FAQ

Does this cell include built-in protection?

No. It is an unprotected industrial cell. A compatible device or finished pack must provide over-charge, over-discharge, over-current, short-circuit, and thermal protection as required by the application.

Is the maximum current the normal operating target?

No. A manufacturer maximum is a limit under stated conditions, not an automatic long-term design target. Use headroom and validate the finished pack under the actual load, duty cycle, cooling, and temperature limits.

Can I solder directly to the cell?

No. Direct soldering can overheat and damage the cell. Use correctly configured spot welding and suitable interconnect material.

Can I mix this cell with another model or an older batch?

Do not mix different models, ages, capacities, internal-resistance groups, batches, or states of charge in one pack. Build with matched cells and balanced parallel groups.

Can I carry or store the cell loose?

No. Isolate the terminals in a protective case or insulated packaging. Never carry loose cells with keys, coins, tools, or other conductive objects.