Manufacturer data sheet

Cell at a glance

5000 mAh Rated capacity
3.6V Nominal voltage
18 Wh Nominal energy
70A Maximum current basis
10A Maximum charge current
21700 Cell format

Manufacturer datasheet matched

Full technical specification

Store SKUEVE-50PL-21700-B1
Manufacturer / modelEVE INR21700/50PL
Format / chemistry21700 / Li-ion
Rated capacity5000 mAh (minimum 5000 mAh)
Nominal voltage3.6V
Full-charge voltage4.2V
Discharge cutoff voltage2.5V
Standard charge current2.5A
Maximum charge current10A
Continuous discharge rating70A
Initial internal resistance<=5 mOhm
Weight68g
DimensionsDiameter 21.15+/-0.10mm, Height 70.15+/-0.15mm
Charge temperature range0C to 60C
Discharge temperature range-20C to 80C
Cycle-life referenceCapacity >=60% after 400 cycles; charge 10A to 4.20V, 0.1A cutoff; discharge 40A to 2.50V or 75 degrees C cutoff; rest 10 min aft
ProtectionUnprotected industrial cell. The finished device or battery pack must provide appropriate protection.

Simple selection guide

Is this the right cell for your build?

Match the cell to the job, then confirm the manufacturer limits for the finished pack.

Best match

High-load packs that also need strong runtime, including RC, UAV, mobility, tools, and compact performance builds within the data sheet limits.

A better alternative when

Choose a high-capacity cell when maximum runtime at modest current matters more, or a dedicated power cell when minimum voltage sag matters more than capacity.

Application guide

Where this cell fits

Fast guidance for common pack types.
Best fit

RC / UAV, power tools, e-bike / mobility, runtime-focused packs

Validate first

Energy storage and backup systems

Avoid

Vape and e-cigarette devices

Keep the finished pack within every manufacturer voltage, current, and temperature limit.

Engineering limits

Current limits

Manufacturer continuous-discharge ratings only. Pulse and over-current laboratory values stay on BatteryRealData.
Continuous discharge rating 70A Planner reference
What this means

The displayed continuous limit comes from the matched manufacturer data sheet. Use design headroom and validate heat in the finished pack.

Show current and runtime examples Optional 1C references and idealized runtime estimates

Current envelope

Relative current values from the matched manufacturer data sheet. Bar length is comparative, not a recommendation.

1C
5A
Continuous
70A

Current and runtime translation

Idealized constant-current runtime based on nominal capacity. Real packs deliver less because voltage sag, heat, cutoff voltage, and losses matter.

0.2C / 1A
300 min
0.5C / 2.5A
120 min
1C / 5A
60 min
At continuous limit
4.29 min
These are mathematical estimates, not guaranteed run times or instructions to operate at the maximum rating.

Real discharge testing

Tested by BatteryRealData

This Shopify summary includes only tests at or below the published 70A continuous-current ceiling.

Highest measured raw capacity 1A constant-current test
EVE 50PL 1A discharge plot showing voltage and cell temperature versus measured capacity
Voltage Cell temperature
Raw capacity
5135 mAh
Raw energy
18.48 Wh
Max observed temp
26.9C
Completed to the configured cutoff
Highest datasheet-range current 70A constant-current test
EVE 50PL 70A discharge plot showing voltage and cell temperature versus measured capacity
Voltage Cell temperature
Raw capacity
2181 mAh
Raw energy
7.55 Wh
Max observed temp
80C
Test stopped before its target cutoff at 3.38V

These curves are observed laboratory results, not operating recommendations. Voltage and temperature are plotted against measured raw capacity for the selected run.

13 datasheet-range discharge tests

Displayed test-current range: 1A to 70A

Best raw capacity
5135 mAh
Best raw energy
18.48 Wh
Published continuous-current ceiling
70A

Only tests inside the matched data sheet continuous-current range are summarized here. BatteryRealData may separately include controlled pulse or over-current research; those laboratory stress tests are not product ratings or operating instructions.

View datasheet-range graphs and test results

Pack planning aid

Current per cell calculator

Enter the total pack current and the number of parallel cells. This checks current sharing against the unconditional continuous value listed above.
Calculated current per cell 70A

Planning aid only. It assumes equal current sharing between matched cells. It does not account for heat, aging, imbalance, conductor resistance, duty cycle, enclosure airflow, or BMS limits.

Read before purchase and use

Safety warning for lithium-ion battery usage

Customers should understand lithium-ion battery handling and safety before purchase. Lithium-ion cells can cause fire, burns, venting, or explosion if misused, overcharged, shorted, crushed, punctured, overheated, or physically damaged.

Use only with a compatible lithium-ion charger, BMS, or protection circuit designed for the cell voltage, current, and temperature limits. Never leave batteries charging unattended. Charge and store on a fire-resistant surface away from combustible materials.

By purchasing and using lithium-ion cells, the user assumes responsibility for correct handling, storage, charging, pack design, and application suitability.

Important usage guidelines

  • Not for use in e-cigarettes, vape devices, or similar devices.
  • Always use in a protected battery pack or properly controlled test fixture.
  • Do not exceed the data sheet maximum charge voltage.
  • Do not discharge below the recommended system cutoff voltage.
  • Do not charge or discharge outside the data sheet temperature limits.
  • Do not carry loose cells in pockets, bags, or toolboxes where they can contact keys, coins, tools, or other metal objects.
  • Store and ship cells in protective cases or insulated packaging.
  • Do not use batteries with torn wrappers, missing insulator rings, dents, rust, odor, leakage, deformation, heat damage, or visible damage.
  • Do not solder directly onto cell terminals. Use proper spot-welding methods only.
  • Do not alter, dismantle, puncture, crush, burn, immerse in liquid, or expose cells to open flame.
  • Keep away from children and pets.
For resellers

Pass all safety information to end users to promote safe handling, correct pack design, and proper use.

Common questions

EVE 50PL FAQ

Does this cell include built-in protection?

No. It is an unprotected industrial cell. A compatible device or finished pack must provide over-charge, over-discharge, over-current, short-circuit, and thermal protection as required by the application.

Is the maximum current the normal operating target?

No. A manufacturer maximum is a limit under stated conditions, not an automatic long-term design target. Use headroom and validate the finished pack under the actual load, duty cycle, cooling, and temperature limits.

Can I solder directly to the cell?

No. Direct soldering can overheat and damage the cell. Use correctly configured spot welding and suitable interconnect material.

Can I mix this cell with another model or an older batch?

Do not mix different models, ages, capacities, internal-resistance groups, batches, or states of charge in one pack. Build with matched cells and balanced parallel groups.

Can I carry or store the cell loose?

No. Isolate the terminals in a protective case or insulated packaging. Never carry loose cells with keys, coins, tools, or other conductive objects.

You may also like

Recently viewed