DIY500AMP Cell Intelligence

LG M58T

Best when runtime is the priority and each cell stays within the datasheet current rating.

High Capacity Cell Low Current Cell High Runtime

Manufacturer data sheet

Cell at a glance

5570 mAh Rated capacity
3.59V Nominal voltage
20 Wh Nominal energy
12.5A maximum with voltage and temperature protection Maximum current basis
To 4.20V: 1.12A at 0C to 10C; 2.7A at 10C to 50C Maximum charge current
21700 Cell format

LG manufacturer draft; marked NOT FINAL VERSION

Full technical specification

Store SKULG-M58T-21700-B1
Manufacturer / modelLG INR21700M58T
Format / chemistry21700 / Li-ion
Rated capacity5570 mAh
Nominal voltage3.59V
Full-charge voltage4.2V
Discharge cutoff voltage2.5V
Standard charge current1.12A
Maximum charge currentTo 4.20V: 1.12A at 0C to 10C; 2.7A at 10C to 50C
Continuous discharge rating12.5A maximum with voltage and temperature protection
Initial internal resistance<=15 mOhm
Weight73.2g
DimensionsDiameter 21.30-21.80 mm; height 70.50-71.00 mm
Charge temperature rangeAmbient 0C to 50C; cell surface 0C to 55C; current derating applies
Discharge temperature rangeAmbient -20C to 60C; cell surface -20C to 70C
Cycle-life reference500 cycles >=80% recovered energy at 2.7A charge / 7.5A discharge.
ProtectionUnprotected industrial cell. The finished device or battery pack must provide appropriate protection.

Simple selection guide

Is this the right cell for your build?

Match the cell to the job, then confirm the manufacturer limits for the finished pack.

Best match

Long-runtime packs, backup power, portable energy, and multi-parallel systems with carefully controlled current per cell.

A better alternative when

Choose a power or hybrid cell when the load needs stronger current delivery or lower voltage sag than this cell is designed to provide.

Application guide

Where this cell fits

Fast guidance for common pack types.
Best fit

Runtime-focused packs, energy storage, backup systems

Validate first

E-bike / mobility only after current and thermal validation

Avoid

High-current tools, RC / UAV, vape and e-cigarette devices

Keep the finished pack within every manufacturer voltage, current, and temperature limit.

Engineering limits

Current limits

Manufacturer continuous-discharge ratings only. Pulse and over-current laboratory values stay on BatteryRealData.
Continuous discharge rating 12.5A maximum with voltage and temperature protection
What this means

LG's draft specification allows 5A charging only at 10C to 40C with a reduced 4.0V cutoff, and warns that repeated cycling at that setting is not preferred; performance and safety are not guaranteed after more than 10 cycles. For 4.20V charging, use the lower temperature-dependent limits shown above. Discharge requires thermal derating and cutoff before the surface-temperature limit; restart below 50C. Maximum ratings are not recommended long-term pack currents.

Show current and runtime examples Optional 1C references and idealized runtime estimates

Current envelope

Relative current values from the matched manufacturer data sheet. Bar length is comparative, not a recommendation.

1C
5.57A
Continuous
12.5A maximum with voltage and temperature protection

Current and runtime translation

Idealized constant-current runtime based on nominal capacity. Real packs deliver less because voltage sag, heat, cutoff voltage, and losses matter.

0.2C / 1.11A
300 min
0.5C / 2.79A
120 min
1C / 5.57A
60 min
These are mathematical estimates, not guaranteed run times or instructions to operate at the maximum rating.

Real discharge testing

Tested by BatteryRealData

A manufacturer-compliant test summary is not currently shown for this cell. Review the specification notes above. BatteryRealData provides separate laboratory context.

Only tests inside the matched data sheet continuous-current range are summarized here. BatteryRealData may separately include controlled pulse or over-current research; those laboratory stress tests are not product ratings or operating instructions.

View BatteryRealData laboratory tests

Read before purchase and use

Safety warning for lithium-ion battery usage

Customers should understand lithium-ion battery handling and safety before purchase. Lithium-ion cells can cause fire, burns, venting, or explosion if misused, overcharged, shorted, crushed, punctured, overheated, or physically damaged.

Use only with a compatible lithium-ion charger, BMS, or protection circuit designed for the cell voltage, current, and temperature limits. Never leave batteries charging unattended. Charge and store on a fire-resistant surface away from combustible materials.

By purchasing and using lithium-ion cells, the user assumes responsibility for correct handling, storage, charging, pack design, and application suitability.

Important usage guidelines

  • Not for use in e-cigarettes, vape devices, or similar devices.
  • Always use in a protected battery pack or properly controlled test fixture.
  • Do not exceed the data sheet maximum charge voltage.
  • Do not discharge below the recommended system cutoff voltage.
  • Do not charge or discharge outside the data sheet temperature limits.
  • Do not carry loose cells in pockets, bags, or toolboxes where they can contact keys, coins, tools, or other metal objects.
  • Store and ship cells in protective cases or insulated packaging.
  • Do not use batteries with torn wrappers, missing insulator rings, dents, rust, odor, leakage, deformation, heat damage, or visible damage.
  • Do not solder directly onto cell terminals. Use proper spot-welding methods only.
  • Do not alter, dismantle, puncture, crush, burn, immerse in liquid, or expose cells to open flame.
  • Keep away from children and pets.
For resellers

Pass all safety information to end users to promote safe handling, correct pack design, and proper use.

Common questions

LG M58T FAQ

Does this cell include built-in protection?

No. It is an unprotected industrial cell. A compatible device or finished pack must provide over-charge, over-discharge, over-current, short-circuit, and thermal protection as required by the application.

Is the maximum current the normal operating target?

No. A manufacturer maximum is a limit under stated conditions, not an automatic long-term design target. Use headroom and validate the finished pack under the actual load, duty cycle, cooling, and temperature limits.

Can I solder directly to the cell?

No. Direct soldering can overheat and damage the cell. Use correctly configured spot welding and suitable interconnect material.

Can I mix this cell with another model or an older batch?

Do not mix different models, ages, capacities, internal-resistance groups, batches, or states of charge in one pack. Build with matched cells and balanced parallel groups.

Can I carry or store the cell loose?

No. Isolate the terminals in a protective case or insulated packaging. Never carry loose cells with keys, coins, tools, or other conductive objects.