Manufacturer data sheet

Cell at a glance

6000 mAh Rated capacity
3.6V Nominal voltage
21.6 Wh Nominal energy
60A temp-limited Maximum current basis
16A Maximum charge current
21700 Cell format

Manufacturer datasheet matched

Full technical specification

Store SKUTP-60XG-21700-6000-60A
Manufacturer / modelTenpower INR21700-60XG
Format / chemistry21700 / NCA
Rated capacity6000 mAh (minimum 5850 mAh)
Nominal voltage3.6V
Full-charge voltage4.2V
Discharge cutoff voltage2.5V
Standard charge current3A
Maximum charge current16A
Continuous discharge rating40A
Temperature-limited continuous rating60A
Initial internal resistance<=5 mOhm
Weight76g
DimensionsDiameter <=21.50mm, height <=70.50mm; negative-side prohibited welding area φ3.5mm
Discharge temperature rangeUp to 80C
Cycle-life reference>=70% initial capacity after 300 cycles, charge 6A to 4.2V CCCV 100mA cutoff, discharge 40A to 2.5V or 75 degrees C cutoff
ProtectionUnprotected industrial cell. The finished device or battery pack must provide appropriate protection.

Simple selection guide

Is this the right cell for your build?

Match the cell to the job, then confirm the manufacturer limits for the finished pack.

Best match

High-load packs that also need strong runtime, including RC, UAV, mobility, tools, and compact performance builds within the data sheet limits.

A better alternative when

Choose a high-capacity cell when maximum runtime at modest current matters more, or a dedicated power cell when minimum voltage sag matters more than capacity.

Application guide

Where this cell fits

Fast guidance for common pack types.
Best fit

RC / UAV, power tools, e-bike / mobility, runtime-focused packs

Validate first

Energy storage and backup systems

Avoid

Vape and e-cigarette devices

Keep the finished pack within every manufacturer voltage, current, and temperature limit.

Engineering limits

Current limits

Manufacturer continuous-discharge ratings only. Pulse and over-current laboratory values stay on BatteryRealData.
Continuous discharge rating 40A Planner reference
Temperature-limited continuous rating 60A Requires the published temperature cutoff
What this means

The 60A value is temperature-limited. The pack planner uses the 40A continuous value without that higher-temperature condition and the 75C cutoff condition.

Show current and runtime examples Optional 1C references and idealized runtime estimates

Current envelope

Relative current values from the matched manufacturer data sheet. Bar length is comparative, not a recommendation.

1C
6A
Continuous
40A
Temp limited
60A

Current and runtime translation

Idealized constant-current runtime based on nominal capacity. Real packs deliver less because voltage sag, heat, cutoff voltage, and losses matter.

0.2C / 1.2A
300 min
0.5C / 3A
120 min
1C / 6A
60 min
At continuous limit
9 min
These are mathematical estimates, not guaranteed run times or instructions to operate at the maximum rating.

Real discharge testing

Tested by BatteryRealData

This Shopify summary includes only tests at or below the published 60A temp-limited continuous-current ceiling.

Highest measured raw capacity 1A constant-current test
Tenpower 60XG 1A discharge plot showing voltage and cell temperature versus measured capacity
Voltage Cell temperature
Raw capacity
6174 mAh
Raw energy
21.74 Wh
Max observed temp
26.5C
Completed to the configured cutoff
Highest datasheet-range current 60A constant-current test
Tenpower 60XG 60A discharge plot showing voltage and cell temperature versus measured capacity
Voltage Cell temperature
Raw capacity
2317 mAh
Raw energy
8.36 Wh
Max observed temp
75.1C
Test stopped before its target cutoff at 3.53V

This run uses the manufacturer's temperature-limited current rating.

These curves are observed laboratory results, not operating recommendations. Voltage and temperature are plotted against measured raw capacity for the selected run.

12 datasheet-range discharge tests

Displayed test-current range: 1A to 60A

Best raw capacity
6174 mAh
Best raw energy
21.74 Wh
Published continuous-current ceiling
60A temp-limited

Only tests inside the matched data sheet continuous-current range are summarized here. BatteryRealData may separately include controlled pulse or over-current research; those laboratory stress tests are not product ratings or operating instructions.

View datasheet-range graphs and test results

Pack planning aid

Current per cell calculator

Enter the total pack current and the number of parallel cells. This checks current sharing against the unconditional continuous value listed above.
Calculated current per cell 40A

Planning aid only. It assumes equal current sharing between matched cells. It does not account for heat, aging, imbalance, conductor resistance, duty cycle, enclosure airflow, or BMS limits.

Read before purchase and use

Safety warning for lithium-ion battery usage

Customers should understand lithium-ion battery handling and safety before purchase. Lithium-ion cells can cause fire, burns, venting, or explosion if misused, overcharged, shorted, crushed, punctured, overheated, or physically damaged.

Use only with a compatible lithium-ion charger, BMS, or protection circuit designed for the cell voltage, current, and temperature limits. Never leave batteries charging unattended. Charge and store on a fire-resistant surface away from combustible materials.

By purchasing and using lithium-ion cells, the user assumes responsibility for correct handling, storage, charging, pack design, and application suitability.

Important usage guidelines

  • Not for use in e-cigarettes, vape devices, or similar devices.
  • Always use in a protected battery pack or properly controlled test fixture.
  • Do not exceed the data sheet maximum charge voltage.
  • Do not discharge below the recommended system cutoff voltage.
  • Do not charge or discharge outside the data sheet temperature limits.
  • Do not carry loose cells in pockets, bags, or toolboxes where they can contact keys, coins, tools, or other metal objects.
  • Store and ship cells in protective cases or insulated packaging.
  • Do not use batteries with torn wrappers, missing insulator rings, dents, rust, odor, leakage, deformation, heat damage, or visible damage.
  • Do not solder directly onto cell terminals. Use proper spot-welding methods only.
  • Do not alter, dismantle, puncture, crush, burn, immerse in liquid, or expose cells to open flame.
  • Keep away from children and pets.
For resellers

Pass all safety information to end users to promote safe handling, correct pack design, and proper use.

Common questions

Tenpower 60XG FAQ

Does this cell include built-in protection?

No. It is an unprotected industrial cell. A compatible device or finished pack must provide over-charge, over-discharge, over-current, short-circuit, and thermal protection as required by the application.

Is the maximum current the normal operating target?

No. A manufacturer maximum is a limit under stated conditions, not an automatic long-term design target. Use headroom and validate the finished pack under the actual load, duty cycle, cooling, and temperature limits.

Can I solder directly to the cell?

No. Direct soldering can overheat and damage the cell. Use correctly configured spot welding and suitable interconnect material.

Can I mix this cell with another model or an older batch?

Do not mix different models, ages, capacities, internal-resistance groups, batches, or states of charge in one pack. Build with matched cells and balanced parallel groups.

Can I carry or store the cell loose?

No. Isolate the terminals in a protective case or insulated packaging. Never carry loose cells with keys, coins, tools, or other conductive objects.

You may also like

Recently viewed